Send Message

               Shenzhen Viyork technology co., LTD

 

                 We will focus more for your attention!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsProgrammable Logic Controller

Fx1n-40mr-D Programmable Logic Controller Module Mitsubishi Plc Communication Module

I'm Online Chat Now
Great communication., A+ pleasure to do business with, Highly recommend.

—— Michael

Great Suppliers it’s a pleasure to work with you

—— David

quick shipping works great thanks

—— Elaine

Fx1n-40mr-D Programmable Logic Controller Module Mitsubishi Plc Communication Module

Fx1n-40mr-D  Programmable Logic Controller Module Mitsubishi Plc Communication Module
Fx1n-40mr-D  Programmable Logic Controller Module Mitsubishi Plc Communication Module Fx1n-40mr-D  Programmable Logic Controller Module Mitsubishi Plc Communication Module

Large Image :  Fx1n-40mr-D Programmable Logic Controller Module Mitsubishi Plc Communication Module Get Best Price

Product Details:

Place of Origin: Japan
Brand Name: Mitsubishi
Certification: CE
Model Number: FX1N-40MR-D

Payment & Shipping Terms:

Minimum Order Quantity: 1 PC
Price: 1-500USD
Packaging Details: New in Original box
Delivery Time: 2-3 days
Payment Terms: T/T, Western Union
Supply Ability: 30 PCS/ PER Month
Detailed Product Description
Brand: Mitsubishi Model: FX1N-40MR-D
Type: Programmable Logic Controller Country Of Origin: Japan
Power Supply: 100-240V Out Put: 24PIN
High Light:

digital temperature controller

,

plc relay module

NEW MODULE FX1N-40MR-D PROGRAMMABLE CONTROLLER PLC MITSUBISHI

 

Quick Details:

 

  • MITSUBISHI

  • FX1N-40MR-D

  • FX1N40MRD

  • DC BASE UNIT24DC IN/16 RELAY OUT

  • One Year Warranty

 

Description:

  • Manufacturer : Mitsubishi Electric

  • FX1N-40MR-D

  • FX1N series FX1N-40MR-D

  • Arithmetic control method : Stored program iterative calculation method with interrupt instruction

  • Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function

  • Programming language : Relay symbol method + step ladder method (SFC expressible)

  • Program memory Maximum memory capacity : 8000 step comments, maximum 8000 steps including file register

  • Internal memory capacity / format : 8000 steps EEPROM (memory backup not required)

  • Memory cassette (memory board) : FX1N-EEPROM-8L (8000 step EEPROM)

  • Write function during RUN : Yes (program changeable during sequencer RUN)

  • Protection function : With password protection function (by keyword function)

  • Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2-digit / 4-digit year AD changeable, monthly difference ± 45 seconds (25 ° C) ※ Note on clock function The current time of the built- It is backed up with. The large capacity condenser (built-in) is fully charged at the energization time of 30 minutes and holds the present value for 10 days. Also, you can hold it with a battery by using an optional battery.

  • Types of instructions Basic instruction : . Sequence instruction: 27 pieces . Step ladder command: 2 pieces

  • Application instruction : Application instruction: 89 kinds

  • Arithmetic processing speed Basic instruction : 0.55 to 0.7 μs / instructions

  • Application instruction : 3.7 to several 100 μs / instructions

  • Number of input / output points Number of input points : 128 points or less (at the time of addition and extension use) However, the input / output total is 128 points or less

  • Number of output points : 128 points or less (at the time of addition and extension use) However, the input / output total is 128 points or less

  • Number of remote I / O points (CC - Link) : 128 points or less including real I / O

  • Total score : 128 points or less (when adding together)

  • device I / O relay Input relay : X000 to X177 128 points (octal number) When added and used

  • Output relay : Y000 to Y177 128 points (octal number) When added and used

  • Auxiliary relay For general use : M 0 to M 383 384 points

  • Keep (EEPROM keep) : M384 to M511 128 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • Keep (capacitor keep) : M512 to M1535 1024 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • Special purpose : M8000 to M8255 256 points

  • State Initial state (EEPROM keep) : S0 to S9 10 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • Keep (EEPROM keep) : S10 to S127 118 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • Keep (capacitor keep) : S128 to S999 872 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • Timer (on-delay) 100 ms : T0 to T199 200 points (0.1 to 3,276.7 seconds)

  • 10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)

  • 1 ms integration type (capacitor keep) : T246 to T249 4 points (0.001 to 32.767 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • 100 ms integration type (capacitor keep) : T250 to T255 6 points (0.1 to 3,276.7 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • Other : Two internal analog volume can be used as analog timer VR 1: D 8030, VR 2: D 8031 ??2 points (0 to 255)

  • counter 16 bit up : C 0 to C 15 16 points (0 to 32,767 counts)

  • 16 bit up (EEPROM keep) : C16 to C31 16 points (0 to 32,767 counts) * Note on keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • 16 bit up (capacitor keep) : C32 to C199 168 points (0 to 32,767 counts) * Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • 32 bit up / down : C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts)

  • 32 bit up / down (capacitor keep) : C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) * Note on Keep Area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • High speed counter : [32-bit high-speed up / down (EEPROM Keep)] C235 ~ C255 1 phase: 60 kHz, 10 kHz 2 phase: 30 kHz, 5 kHz there is a limit to the number and input frequency that can be used according to the conditions used. ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • Data register (32 bits in pair use) For 16-bit general purpose : D0 to D127 128 points

  • For 16-bit keep (EEPROM keep) : D128 to D255 128 points ※ Note on the keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.

  • For 16-bit keep (capacitor keep) : D256 to D7999 7744 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.

  • File register (keep) : D1000 to D7999 Up to 7000 points (It can be set to program area (EEPROM) as file register in units of 500 points from D1000 according to parameters)

  • 16 bit special use : D 8000 to D 8255 256 points

  • For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points

  • Pointer JUMP, for CALL branch : P0 to P127 128 points (for CJ instruction, CALL instruction, P63 for END jump)

  • Input interrupt : I00□ ~ I50□ 6 points

  • nesting : [For master control] N 0 to N 7 8 points (for MC command)

  • constant Decimal number (K) : 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647

  • Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF

  • Rated voltage : 12 to 24 VDC

  • Voltage tolerance range : DC 10.2 to 28.8 V

  • Rated frequency : -

  • Allowable momentary power outage time : Operation continues with an instantaneous blackout of 5 ms or less.

  • Power supply fuse : 125 V 3.15 A

  • Inrush current : Up to 25 A 1 ms or less / 24 VDC, 22 A maximum 0.2 ms or less / DC 12 V

  • power consumption : Includes 18 W input current (7 mA or 5 mA per point).

  • 24 VDC service power supply : -

  • Input specification :

  • Number of input points : 24 points

  • Input connection shape : Removable terminal block (M3 screw)

  • Input format : sink

  • Input signal voltage : DC 24 V ± 10%

  • Input impedance X000 to X007 : 3.3 kΩ

  • X010 or later : 4.3 kΩ

  • Input signal current X000 to X007 : 7 mA / 24 VDC

  • X010 or later : 5 mA / 24 VDC

  • Input ON sensitivity current X000 to X007 : 4.5 mA or more

  • X010 or later : 3.5 mA or more

  • Input OFF sensitivity current : 1.5 mA or less

  • Input response time : Approximately 10 ms X000 to X007 have a built-in digital filter and can be changed in 1 ms increments to 0 to 15 ms by D8020. When 0 is specified, X000, X001 is 10 μs, and X002 to X007 is 50 μs.

  • Input signal format : No-voltage contact input NPN open collector transistor

  • Input circuit insulation : Photocoupler insulation

  • Input operation display : LED ON when input is ON

  • Number of output points : 16 points

  • Output connection shape : Terminal block (M3 screw)

  • Output type / format : Relay output

  • External power supply : AC 250 V DC 30 V or less

  • Maximum load Resistive load : 2A or less / per output 8 A or less / per COM terminal

  • Inductive load : 80VA

  • Minimum load : DC 5 V 2 mA (reference value)

  • Open-circuit leakage current : -

  • ON voltage : -

  • Response time OFF → ON : About 10 ms

  • ON → OFF : About 10 ms

  • Circuit insulation : Mechanical insulation

  • Output operation indication : LED lit when relay coil is energized

  • Built-in high speed counter function :

  • 1 phase 1 count input : [C235, C236] Up to 2 points: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C237 to C245] Up to 4 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Processed by high- The sum of the frequencies to be summed (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).

  • 1 phase 2 count input : [C246] Maximum 1 point: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C247 to C250] Up to 2 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).

  • 2 phase 2 count input : [C251] Maximum 1 point: Up to 30 kHz High speed comparison When using SET / RESET: 15 kHz [C252 to C255] Up to 2 points: Up to 5 kHz High speed comparison When using SET / RESET: 5 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).

  • Ambient temperature : 0 to 55 ° C. ... Operating, -20 to 70 ° C....when saved

  • Relative humidity : 35 to 85% RH (noncondensing)...at operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

  • Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : When performing the withstand voltage test, make the voltage between each terminal and the ground terminal of the basic unit as follows. Between power supply terminal (DC power supply) and earth terminal: 500 VAC for 1 minute Between output terminal (relay) and earth terminal: AC 1.5 kV 1 min

  • Insulation resistance : When conducting the insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (DC power supply) and earth terminal: 500 VDC DC insulation resistance meter 5 MΩ or more Output terminal (relay) and earth terminal: 500 VDC with insulation resistance meter 5 MΩ or more

  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding must be dedicated ground or common ground.

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.7 Kg

 

FX1N Series Programmable Logic Controllers

Product introduction

Model Description
FX1N-14MR-001 basic unit, built-in 8 in /6 out (relay), AC power supply
FX1N-14MT-001 basic unit, built-in 8 in /6 out (relay), AC power supply
FX1N-24MR-001 basic unit, built-in 14 in /10 out (relay), AC power supply
FX1N-40MR-001 basic unit, built-in 24 in /16 out (relay), AC power supply
FX1N-60MR-001 basic unit, built-in 36 in /24 out (relay), AC power supply
FX1N-14MT-001 basic unit, built-in 8 input /6 out (transistor), AC power supply
FX1N-24MT-001 basic unit, built-in 14 input /10 out (transistor), AC power supply
FX1N-40MT-001 basic unit, built-in 24 input /16 out (transistor), AC power supply
FX1N-60MT-001 basic unit, built-in 36 input /24 out (transistor), AC power supply

 

MORE INFORMATION

DELIVERY
 
Logistic partners UPS, FedEx and DHL
 
International delivery available
 
Same day dispatch from group stock
 
WARRANTY
 
All parts new are covered by Shenzhen Viyork 12 month warranty
 
RETURNS
 
No hassle returns policy
 
Dedicated customer support team
 
PAYMENT
 
Trade credit
 
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
 
Payment options
 
We accept Bank transfers and the following methods of payment:
 
Western Union PayPal VISA
 
Pls contact us:
Company: Shenzhen Viyork Technology CO.,LTD.
Cotact:Miss Liu
Moblie/WhatsApp: 0086-13826534820
Email: shenzhenviyork@163.com
Skype:live:.cid.ba9401e01ca235c2

 

Fx1n-40mr-D  Programmable Logic Controller Module Mitsubishi Plc Communication Module 0

 

 

Contact Details
Shenzhen Viyork Technology Co., LTD

Contact Person: Sophey Guo

Tel: 086-13798305309

Send your inquiry directly to us