Product Details:
Payment & Shipping Terms:
|
Brand: | Mitsubishi | Model: | FX1N-40MR-D |
---|---|---|---|
Type: | Programmable Logic Controller | Country Of Origin: | Japan |
Power Supply: | 100-240V | Out Put: | 24PIN |
Highlight: | digital temperature controller,plc relay module |
NEW MODULE FX1N-40MR-D PROGRAMMABLE CONTROLLER PLC MITSUBISHI
Quick Details:
MITSUBISHI
FX1N-40MR-D
FX1N40MRD
DC BASE UNIT24DC IN/16 RELAY OUT
One Year Warranty
Description:
Manufacturer : Mitsubishi Electric
FX1N-40MR-D
FX1N series FX1N-40MR-D
Arithmetic control method : Stored program iterative calculation method with interrupt instruction
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Program memory Maximum memory capacity : 8000 step comments, maximum 8000 steps including file register
Internal memory capacity / format : 8000 steps EEPROM (memory backup not required)
Memory cassette (memory board) : FX1N-EEPROM-8L (8000 step EEPROM)
Write function during RUN : Yes (program changeable during sequencer RUN)
Protection function : With password protection function (by keyword function)
Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2-digit / 4-digit year AD changeable, monthly difference ± 45 seconds (25 ° C) ※ Note on clock function The current time of the built- It is backed up with. The large capacity condenser (built-in) is fully charged at the energization time of 30 minutes and holds the present value for 10 days. Also, you can hold it with a battery by using an optional battery.
Types of instructions Basic instruction : . Sequence instruction: 27 pieces . Step ladder command: 2 pieces
Application instruction : Application instruction: 89 kinds
Arithmetic processing speed Basic instruction : 0.55 to 0.7 μs / instructions
Application instruction : 3.7 to several 100 μs / instructions
Number of input / output points Number of input points : 128 points or less (at the time of addition and extension use) However, the input / output total is 128 points or less
Number of output points : 128 points or less (at the time of addition and extension use) However, the input / output total is 128 points or less
Number of remote I / O points (CC - Link) : 128 points or less including real I / O
Total score : 128 points or less (when adding together)
device I / O relay Input relay : X000 to X177 128 points (octal number) When added and used
Output relay : Y000 to Y177 128 points (octal number) When added and used
Auxiliary relay For general use : M 0 to M 383 384 points
Keep (EEPROM keep) : M384 to M511 128 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Keep (capacitor keep) : M512 to M1535 1024 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
Special purpose : M8000 to M8255 256 points
State Initial state (EEPROM keep) : S0 to S9 10 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Keep (EEPROM keep) : S10 to S127 118 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Keep (capacitor keep) : S128 to S999 872 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
Timer (on-delay) 100 ms : T0 to T199 200 points (0.1 to 3,276.7 seconds)
10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)
1 ms integration type (capacitor keep) : T246 to T249 4 points (0.001 to 32.767 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
100 ms integration type (capacitor keep) : T250 to T255 6 points (0.1 to 3,276.7 seconds) * Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
Other : Two internal analog volume can be used as analog timer VR 1: D 8030, VR 2: D 8031 ??2 points (0 to 255)
counter 16 bit up : C 0 to C 15 16 points (0 to 32,767 counts)
16 bit up (EEPROM keep) : C16 to C31 16 points (0 to 32,767 counts) * Note on keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
16 bit up (capacitor keep) : C32 to C199 168 points (0 to 32,767 counts) * Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
32 bit up / down : C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts)
32 bit up / down (capacitor keep) : C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) * Note on Keep Area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
High speed counter : [32-bit high-speed up / down (EEPROM Keep)] C235 ~ C255 1 phase: 60 kHz, 10 kHz 2 phase: 30 kHz, 5 kHz there is a limit to the number and input frequency that can be used according to the conditions used. ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Data register (32 bits in pair use) For 16-bit general purpose : D0 to D127 128 points
For 16-bit keep (EEPROM keep) : D128 to D255 128 points ※ Note on the keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
For 16-bit keep (capacitor keep) : D256 to D7999 7744 points ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) Large capacity condenser (built-in) will be fully charged at 30 minutes of energization time and hold the present value for 10 days. If the voltage of the large capacity capacitor decreases, the state of the capacitor keeping device may not be held correctly. Please initialize the capacitor keep device when using for the first time after purchasing the FX1N series sequencer or after using it for a long time not to turn on the power supply. Before resuming operation, please set the device and current time required for driving.
File register (keep) : D1000 to D7999 Up to 7000 points (It can be set to program area (EEPROM) as file register in units of 500 points from D1000 according to parameters)
16 bit special use : D 8000 to D 8255 256 points
For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points
Pointer JUMP, for CALL branch : P0 to P127 128 points (for CJ instruction, CALL instruction, P63 for END jump)
Input interrupt : I00□ ~ I50□ 6 points
nesting : [For master control] N 0 to N 7 8 points (for MC command)
constant Decimal number (K) : 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647
Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF
Rated voltage : 12 to 24 VDC
Voltage tolerance range : DC 10.2 to 28.8 V
Rated frequency : -
Allowable momentary power outage time : Operation continues with an instantaneous blackout of 5 ms or less.
Power supply fuse : 125 V 3.15 A
Inrush current : Up to 25 A 1 ms or less / 24 VDC, 22 A maximum 0.2 ms or less / DC 12 V
power consumption : Includes 18 W input current (7 mA or 5 mA per point).
24 VDC service power supply : -
Input specification :
Number of input points : 24 points
Input connection shape : Removable terminal block (M3 screw)
Input format : sink
Input signal voltage : DC 24 V ± 10%
Input impedance X000 to X007 : 3.3 kΩ
X010 or later : 4.3 kΩ
Input signal current X000 to X007 : 7 mA / 24 VDC
X010 or later : 5 mA / 24 VDC
Input ON sensitivity current X000 to X007 : 4.5 mA or more
X010 or later : 3.5 mA or more
Input OFF sensitivity current : 1.5 mA or less
Input response time : Approximately 10 ms X000 to X007 have a built-in digital filter and can be changed in 1 ms increments to 0 to 15 ms by D8020. When 0 is specified, X000, X001 is 10 μs, and X002 to X007 is 50 μs.
Input signal format : No-voltage contact input NPN open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED ON when input is ON
Number of output points : 16 points
Output connection shape : Terminal block (M3 screw)
Output type / format : Relay output
External power supply : AC 250 V DC 30 V or less
Maximum load Resistive load : 2A or less / per output 8 A or less / per COM terminal
Inductive load : 80VA
Minimum load : DC 5 V 2 mA (reference value)
Open-circuit leakage current : -
ON voltage : -
Response time OFF → ON : About 10 ms
ON → OFF : About 10 ms
Circuit insulation : Mechanical insulation
Output operation indication : LED lit when relay coil is energized
Built-in high speed counter function :
1 phase 1 count input : [C235, C236] Up to 2 points: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C237 to C245] Up to 4 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Processed by high- The sum of the frequencies to be summed (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
1 phase 2 count input : [C246] Maximum 1 point: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C247 to C250] Up to 2 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
2 phase 2 count input : [C251] Maximum 1 point: Up to 30 kHz High speed comparison When using SET / RESET: 15 kHz [C252 to C255] Up to 2 points: Up to 5 kHz High speed comparison When using SET / RESET: 5 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
Ambient temperature : 0 to 55 ° C. ... Operating, -20 to 70 ° C....when saved
Relative humidity : 35 to 85% RH (noncondensing)...at operation
Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2
Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
tor with period of 30 to 100 Hz
Withstand voltage : When performing the withstand voltage test, make the voltage between each terminal and the ground terminal of the basic unit as follows. Between power supply terminal (DC power supply) and earth terminal: 500 VAC for 1 minute Between output terminal (relay) and earth terminal: AC 1.5 kV 1 min
Insulation resistance : When conducting the insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (DC power supply) and earth terminal: 500 VDC DC insulation resistance meter 5 MΩ or more Output terminal (relay) and earth terminal: 500 VDC with insulation resistance meter 5 MΩ or more
ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding must be dedicated ground or common ground.
Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
Use altitude : It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down.
Shipping Weight : 1.7 Kg
FX1N Series Programmable Logic Controllers
Product introduction
Model | Description |
FX1N-14MR-001 | basic unit, built-in 8 in /6 out (relay), AC power supply |
FX1N-14MT-001 | basic unit, built-in 8 in /6 out (relay), AC power supply |
FX1N-24MR-001 | basic unit, built-in 14 in /10 out (relay), AC power supply |
FX1N-40MR-001 | basic unit, built-in 24 in /16 out (relay), AC power supply |
FX1N-60MR-001 | basic unit, built-in 36 in /24 out (relay), AC power supply |
FX1N-14MT-001 | basic unit, built-in 8 input /6 out (transistor), AC power supply |
FX1N-24MT-001 | basic unit, built-in 14 input /10 out (transistor), AC power supply |
FX1N-40MT-001 | basic unit, built-in 24 input /16 out (transistor), AC power supply |
FX1N-60MT-001 | basic unit, built-in 36 input /24 out (transistor), AC power supply |
MORE INFORMATION
DELIVERY
Logistic partners UPS, FedEx and DHL
International delivery available
Same day dispatch from group stock
WARRANTY
All parts new are covered by Shenzhen Viyork 12 month warranty
RETURNS
No hassle returns policy
Dedicated customer support team
PAYMENT
Trade credit
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment options
We accept Bank transfers and the following methods of payment:
Western Union PayPal VISA
Pls contact us:
Company: Shenzhen Viyork Technology CO.,LTD.
Cotact:Miss Liu
Moblie/WhatsApp: 0086-13826534820
Email: shenzhenviyork@163.com
Skype:live:.cid.ba9401e01ca235c2
Contact Person: Sophey Guo
Tel: 086-13798305309